background image

Page 6

60706-246

4200-00

charger plugged in. Storing the unit without the power

switch turned off will cause the battery to drain as the

DSE-730 is powered up. This switch is bypassed when

the unit is running to prevent the controller from being

shutoff with the engine running.

G - USB Port. This port is used to program the DSE-

730 Controller from a computer using the DEEP SEA

Software. If needed the DEEP SEA software can be

down loaded for the their web site.

(www.deepseaplc.com)

H - DSE-7310 Generator Control. See Explanation on

page 4.

J -Emergency Stop Switch (3)- When depressed

this switch will disconnect all the 2 volt power to the

DSE-730 shutting the engine down. The lamp in the

emergency stop switch will light up when the switch is

depressed showing that the power to the panel has been

disconnected.

K - Voltage Adjust Rheostat. Controls the output voltage

of the generator by varying voltage regulators reference

voltage. This trim pot is used to adjust the voltage after

you switch between the different voltages on the Selector

Switch. A wide range of voltages are available with 4 posi-

tion selector switch and rheostat.

FRONT PANEL LAYOUT

2. FRONT PANEL LAYOUT

A - Selector Switch Safety Release. This safety button

must be depressed before you can change the selector

switch. Depressing this will also kill the engine, this is to

ensure the unit is not running when the selector switch is

changed.

B - Voltage Selector Switch. This heavy duty four posi-

tion switch allows the operator to quickly and safely re-

connect the 2 lead generator to any one of four output

voltages. Once the output voltage is selected, the switch

will lock to prevent it from accidentally being changed

during operation. (See "A" above)

C - AC Control Fuses (3 each). These 2 amp fuses

limit the AC input into the DSE-730 controller prevent-

ing it from being damaged.

(Replacement Fuse 2 Amp ATO-ATC)

D - DSE7310 Fuse. This 3 amp DC fuse protects the

DSE-730 printed circuit board.

(Replacement Fuse 3 Amp ATO-ATC)

E - DC Control Circuit Fuse. The 0 amp DC Circuit

Fuse protects the 2 volt circuits and engine wiring har-

ness against faults in wiring or control equipment. The

fuse also prevents a discharge of the battery due to a

circuit fault. (Replacement Fuse 0 Amp ATO-ATC)

F - Generator Control Power Switch. This switch

disconnects all power to the DSE-730 Engine Control.

This switch should be turn off anytime the unit is going

to be stored longer than over night with out the battery