60706-246
4200-00
charger plugged in. Storing the unit without the power
switch turned off will cause the battery to drain as the
DSE-730 is powered up. This switch is bypassed when
the unit is running to prevent the controller from being
shutoff with the engine running.
G - USB Port. This port is used to program the DSE-
730 Controller from a computer using the DEEP SEA
Software. If needed the DEEP SEA software can be
down loaded for the their web site.
(www.deepseaplc.com)
H - DSE-7310 Generator Control. See Explanation on
page 4.
J -Emergency Stop Switch (3)- When depressed
this switch will disconnect all the 2 volt power to the
DSE-730 shutting the engine down. The lamp in the
emergency stop switch will light up when the switch is
depressed showing that the power to the panel has been
disconnected.
K - Voltage Adjust Rheostat. Controls the output voltage
of the generator by varying voltage regulators reference
voltage. This trim pot is used to adjust the voltage after
you switch between the different voltages on the Selector
Switch. A wide range of voltages are available with 4 posi-
tion selector switch and rheostat.
FRONT PANEL LAYOUT
2. FRONT PANEL LAYOUT
A - Selector Switch Safety Release. This safety button
must be depressed before you can change the selector
switch. Depressing this will also kill the engine, this is to
ensure the unit is not running when the selector switch is
changed.
B - Voltage Selector Switch. This heavy duty four posi-
tion switch allows the operator to quickly and safely re-
connect the 2 lead generator to any one of four output
voltages. Once the output voltage is selected, the switch
will lock to prevent it from accidentally being changed
during operation. (See "A" above)
C - AC Control Fuses (3 each). These 2 amp fuses
limit the AC input into the DSE-730 controller prevent-
ing it from being damaged.
(Replacement Fuse 2 Amp ATO-ATC)
D - DSE7310 Fuse. This 3 amp DC fuse protects the
DSE-730 printed circuit board.
(Replacement Fuse 3 Amp ATO-ATC)
E - DC Control Circuit Fuse. The 0 amp DC Circuit
Fuse protects the 2 volt circuits and engine wiring har-
ness against faults in wiring or control equipment. The
fuse also prevents a discharge of the battery due to a
circuit fault. (Replacement Fuse 0 Amp ATO-ATC)
F - Generator Control Power Switch. This switch
disconnects all power to the DSE-730 Engine Control.
This switch should be turn off anytime the unit is going
to be stored longer than over night with out the battery