Wilkerson DE5 User Manual
Page 13
Instruction Manual / DE3, DE4 and DE5
Wilkerson Compact Heatless Air Dryers
MODELS DE3, DE4 AND DE5 TROUBLESHOOTING GUIDE
D
PROBLEM: ALARM WILL NOT CLEAR
POSSIBLE CAUSE
CHECK
CORRECTIVE ACTION
D1
Wet air condition not corrected. See Section "A" of
Troubleshooting Guide.
D2
Sensor not dried out.
Allow several minutes for
To speed up alarm clearing,
sensor to dry out after correcting
bleed some air through tire valve
dryer problem. Alarm should clear.
at bottom of sensor housing.
Alarm should clear in less than
than 60 seconds.
D3
Bad humidistat board.
Disconnect humidity cable from
Replace humidistat board.
sensor. Alarm should clear.