Introduction:

Follow these instructions when installing, operating, or servicing
the product.

Application Limits

These products are intended for use in general purpose
compressed air systems only.

Operating Pressure:

kPa

PSIG

bar

Maximum Inlet Pressure:

Metal Bowl

1734

250

17.3

Poly Bowl

1024

150

10.2

Operating Temperature:

Maximum Temperature (Metal Bowl)

80°C (175°F)

Maximum Temperature (Poly Bowl)

52°C (125°F)

Minimum Temperature

0°C (32°F)

Installation

The right angle bracket can be installed using the two methods
outlined on reverse side. Keep pipe or tubing lengths to a
minimum with inside clean and free of dirt and chips. Pipe
joint compound should be used sparingly and applied only to
the male pipe - never the female port. Do not use PTFE tape
to seal pipe joints - pieces have a tendency to break off and
lodge inside the unit, possibly causing malfunction.

A

B

C

D

E

F

G

H

J

2.83

2.28

1.14

1.16

.28

.43

.28

1.49

2.31

72.0 mm 58.0 mm 29.0 mm

29.5 mm 7.0 mm 11.0 mm 7.0 mm 37.8 mm 58.8 mm

Right Angle Bracket Dimensions

!

!

WARNING

To avoid unpredictable system behavior that can cause personal
injury and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to

this product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.

• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical

supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered

by paint, etc. If masking is not possible, contact your local
representative for replacement labels.

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other information from The Company, its
subsidiaries and authorized distributors provide product and/or system
options for further investigation by users having technical expertise. It
is important that you analyze all aspects of your application, including
consequences of any failure and review the information concerning
the product or systems in the current product catalog. Due to the
variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements
of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject
to change by The Company and its subsidiaries at any time without
notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

Installation & Service Instructions:
83-962-000

12 Series Right Angle Bracket

ISSUED: November, 2001
Supersedes: None

EN# 01085520, Rev.1

6.70

170mm

9.00

229mm

Englewood, CO 80110