INSTALLATION

1.Refer to the warning on front page.
2.Install as close as possible to the equipment requiring lubrication.
3.Install the unit with the air moving through the body in the direction indi-

cated by the arrow.

4.Install a unit with the same pipe size as the line in use. Avoid using

fittings, couplings, etc., that restrict the airflow or baffle the oil out of the
air at the lubricator outlet.

5.The unit may be filled under pressure by removing the fill plug and

pouring the oil into a bowl through the fill port. The bowl may be taken off
after the fill plug is removed if a more rapid fill is required.

DO NOT

replace the fill plug until the bowl and bowl guard are in position and the
clamp ring is locked in place.

NOTE:

As the fill plug is removed, the air

pressure in the bowl will be released.

6.Use only clean nondetergent oil. SAE 10 or lighter is usually best.
7.The rate of oil delivery may be controlled by turning the adjusting screw

counterclockwise for more and clockwise for less oil delivery. This
lubricator delivers all the oil downstream which passes through the sight
dome. The oil delivery rate will change automatically to deliver more oil
during higher airflows and less oil for airflows lower than that at which
the original setting was made.

8.Maximum pressure and temperature ratings for metal tanks

are 200 psig (14 bar) and 175°F (79°C).

MAINTENANCE

1. Given clean operating conditions, this unit will be trouble-free.

Contaminants from dirty oil may collect on the siphon tube inlet filter,
requiring the filter to be cleaned by tapping on a hard surface and
blowing off with an air blow gun.

2. If the oil delivery rate drops, the lubricator should be cleaned. Shut off air

supply and reduce pressure in unit to zero. Remove the Flow-Guide®
variable orifice screw and clean its air passage with a small wire. Check
the bore that the screw fits into for contaminants and clean, if necessary.
Be sure that the passageway from the sight dome cavity into the Flow-
Guide® variable orifice post is open. Remove the adjusting screw and
clean the needle and the seat in the body. Inspect and clean the
passage from the needle seat down into the adapter.

3. Drain off any contaminants which collect in the bottom of the bowl.
4. Lubricate o-rings with Parker O-Lube before assembly.
5. Clean plastic bowl with a clean, dry cloth only.

KITS AND REPLACEMENT PARTS

Repair Kit -(O-Rings) (for L41 and L42).................................LRP-95-061
Siphon Tube Assembly Kit (for L41) ......................................LRP-96-182
Siphon Tube Assembly Kit (for L42) ......................................LRP-96-211
Fill Plug Kit (for L41 and L42) ................................................LRP-95-250
Flow-Guide® Variable Orifice Kit (for L41 and L42) ..............LRP-95-251
Sight Dome Kit (for L41 and L42) ..........................................LRP-95-249
Sight Gauge Kit (for L41) .......................................................LRP-95-771
Sight Gauge Kit (for L42) .......................................................LRP-95-716

Tamper Resistant Kit ...........................................................LRP-95-587

Force-Fill Adapter (for L41 and L42)......................................LRP-96-420
Check Ball and O-Ring Kit .....................................................LRP-95-310