beautypg.com

Service kits available – Wilkerson L12 User Manual

Page 2

background image

1/4" and 3/8" L12 Atomist Lubricators

83-955-000

Polycarbonate
Bowl
(See Warning)
(Do Not Scratch
Internal Surfaces)

Retaining Collar
(Hand Tighten
Plus 1/4 Turn)

Bowl Guard

Metal Bowl
(Sight Glass
Shown)

Manual

Drain

Body Force Fill Adapter Kit

LRP-96-302

Bowl Force Fill Adapter Kit

LRP-96-304

Fill Button Assembly
Torque:
2.8 to 3.4Nm
(35 to 30 in. lbs.)

O-ring

O-ring

Body Force
Fill Adapter
(Hand Tight)

Fill Button Assembly
Torque:
2.8 to 3.4Nm
(35 to 30 in. lbs.)

O-ring

Filter Body
(Internal
Surfaces)

O-ring

O-ring

Fill Plug

Seal

Siphon Tube

Seal

Sight
Dome

Flapper

Service Kits Available

L12

Description

1/4" and 3/8"

Adjustment Knob

LRP-96-300

Bowl Guard Kit

GRP-96-345

Drip Control (Polycarbonate)

LRP-96-307

and Fill Plug Kit
Lubricator Repair Kit

LRP-96-309

Body Force Fill Adaptor Kit

LRP-96-302

Sight Dome Kit

LRP-96-301

Sight Gauge Kit

GRP-96-346

Metal Bowl Kits
Manual Drain

GRP-96-348

Piston Drain

GRP-96-353

Sight Gauge and

GRP-96-349

Manual Drain
Sight Gauge and

LRP-96-305

Force Fill Adapter
Polycarbonate Bowl Kits
Manual Drain

GRP-96-347

Bowl Force Fill Adapter Kit

LRP-96-304

Drain Kits
Manual Drain

GRP-96-340

1

2

3

4

5

6

7

Downstream Delivery DPM

33

67

100

133

167

200

233

Dome Drip Rate DPM

Oil Delivery Conversion

3% of Drip Rate to Downstream

3. Oil delivery adjustment — To adjust oil delivery, turn

adjustment knob on top of the lubricator.

Leaner — Clockwise

Richer — Counterclockwise

By counting the number of drops per minute in the sight
dome, you can adjust to your requirements.

Atomist lubricator — Approximately 3% of the droplets visible
in the sight dome go downstream; adjust drip rate accordingly.
Consult oil delivery conversion chart.

Generally, one drop per minute downstream for every
10 - 15 SCFM flow is satisfactory.

25 drops per minute equals one (1) ounce per hour - volume
of oil passing through the sight dome.

NOTE: This is a constant density type lubricator which delivers a constant
ratio of oil to air flow. Therefore, if air flow increases or decreases, oil
delivery will be adjusted proportionately. ONLY IF A DIFFERENT RATIO
IS DESIRED SHOULD YOUR ADJUSTMENT KNOB SETTING BE
CHANGED AFTER YOUR INITIAL SETTING.

4. To replace fill plug, drip control, and service lubricator:

A. Turn off air supply and depressurize the unit.

B. Refer to pictorial for servicing and torque values.

C. Turn on air supply and check lubricator for leakage. If

leakage occurs, DO NOT OPERATE — conduct repairs
again.

Lightly grease with provided lubricant. (Silicone free)

Inspect for nicks, scratches, and surface imperfections.
If present, reduced service life is probable and future
replacement should be planned.

Clean with lint-free cloth.