beautypg.com

Making zone paging – Toa A-9240SHM2 User Manual

Page 46

background image

Step 1. Close the paging function assigned-control input terminal.

The level of the mixed audio signal being broadcast at the

paging destination decreases.

Step 2. Make a paging call.

Step 3. Open the input terminal that has been closed in the step 1.

The level of the mixed audio signal being broadcast at the
paging destination decreases.

Paging terminates, restoring the level of the mixed audio signal to

the original value.

46

9.3. Making Zone Paging

To make the zone paging broadcast setting easier, clarify the following points before performing the setting.
· Input (source) to access paging broadcast
· Paging trigger and paging destination zones
· Equipment or function to be interlocked with paging

Paging settings are described below.

9.3.1. Zone paging using the D-001T, D-001R, or 900 series module

When using the D-001T, D-001R, or 900 series module for paging input, the paging function for the input
channel must be set to ON in the input settings.
The paging-enabled input channel is set as a paging source, enabling the priority setting, paging trigger
setting, and paging output destination setting.
For each setting item, refer to

p. 54, "Input Setting Flow Chart."

Notes
• If the paging setting of an input channel is changed to OFF from ON during paging, the paging using the

input channel is made to terminate.

• When the paging-enabled input channel is muted, paging can be initiated but the paging call will be muted.

[Paging initiation by means of the control terminal]
When the paging broadcast is initiated by closing the control
terminal (make contact), the following operations are carried
out.

Close (make contact)

Open (break contact)

Contact input

Contact input