Precaution – Tii 356 Series User Manual
Page 2
![background image](/manuals/714069/2/background.png)
5. Loop back unused station wire conductors and
coil around the station wire jacket or store in
such a manner as to prevent them from
coming in contact with protector terminals or
bare wires.
6. When more than one cable is placed under a
nut, use washers between the wires.
7. Use caution when terminating small gauge
Customer Side cable on the protector module
terminals, as the wires may catch in the
threads of the terminal and be cut or broken
when nuts are tightened.
8. Check all nuts to make sure they are tight.
Precaution
1. When clearing trouble on a line that contains
gas tube protector modules, and when the test
board has indicated that there may still be a
power contact, inspect the non-cable portion
of the line from the ground for any power
contacts or evidence of damage from power
contacts.
2. Special care should be taken in making the
inspections where the line runs through trees
or where visibility is limited.
3. If a power contact is found, notify the proper
authority so it may be corrected.
4. Do not work on the line until the power contact
has been cleared.
5. If no contact is found but the test board still
have indications of a power contact, wear
insulating gloves while working with the test
board to clear the line.
Figure 2
Telco Side Cable
Ground
Conductor
Tip
Conductor
Ring
Conductor
Line 1
Protector
Line 2
Protector
Ground
Stud
Typical Installation
Station Protector Housing
(Cover Removed)
Customer Side Cable