Wiring – Tii 506F-03 User Manual
Page 2
Figure 2
Wiring
1. Punch a hole through the left grommet and
guide the Telco Drop Cable through the entry
grommet.
2. Using the FTTX Connector, splice the Telco
Drop Cable and the Customer Fiber Cable
together as required.
3. Install the already spliced FTTX Connector to
the slack tray strain relief using a tie-wrap.
Push the tie-wrap through the provided slots
on the slack tray, wrap over the FTTX
Connector and tighten the tie-wrap.
4. Wrap excess Customer Fiber Cable clockwise
around the slack tray.
5. Wrap the excess drop cable/fiber cable slack
in the clockwise direction and place it into the
base enclosure and under the slack retention
fingers.
6. Use a tie-wrap to hold any spliced connections
and cables to the strain relief pads.
7. Punch a hole through the right grommet and
guide the Customer Fiber Cable through the
Customer Exit Grommet.
8. Close and secure the cover. Tighten the
security hex screw until it is snug. Be sure not
to over tighten the screw.
Figure 3
Internal Mounting
Holes
Entry
Grommet
Exit
Grommet
External Mounting Ears
Tie-Wrap
FTTX
Connector
Telco Drop
Cable
Customer Out
Fiber Cable
1.5” Tall Slack
Tray with
Customer Fiber
Cable Slack
Base
Cable Slack
Strain Relief
Pad with
Tie-Wrap
Slack
Retention
Fingers