Tii 97 User Manual
Page 2
Figure 3
5.
Wiring for Voice and Data Grommet Preparations: If
routing additional wires through the rubber grommet located
at the bottom of the unit, punch a small hole in the grommet.
Do not break through the edge of the grommet. Doing so
may compromise the grommet’s holding ability.
6.
Subscriber Wiring:
Route wires through the grommet located at the bottom of
the unit and dress up to the appropriate module(s).
Dress any excess wire along the sides of the base.
DATA Wiring: Connect the subscriber DATA wires to the
screw terminals on the Standard POTS CBM (Tip to green,
Ring to red) (see Figure 5).
VOICE Wiring: Connect the subscriber VOICE wires to the
screw terminals on the ADSL POTS Splitter Module (Tip to
green, Ring to red).
7.
Wiring to Screw Terminals:
Strip conductor wires back approximately ½ inch.
Wrap the base wire around the screw terminal between two
washers. So not overlap wire on the screws.
Cut off any excess wire after tightening the screw terminal.
8.
Securing the NID Unit: Make sure the wire entrygrommet is
completely seated into position in the base. Tighten the
customer access screw to secure the cover.
Figure 4
Figure 5
Rubber Grommet
Lower Flange
Base Flange
Screwdriver
Release Arm
Center Wall
Latch
TII 9A Adapter
RJ-11 test Auto-Jack
(for testing only)
TII 97 POTS Splitter
Voice Screw
Terminal
Connections
Data Screw Terminal
Connections
Standard POTS Customer
Bridge Module
Subscriber Voice Wires
Subscriber Data Wires (To
Modem)