TII P/N:
92226901
NOTE: IDC’s accept 22-26 AWG solid wire. Wires
should be aligned to the corresponding holes. Green
wire to the “T” (GRN) labeled wire guide and the Red
wire to the “R” (RED) labeled wire guide.
4.11
Insert wires into wire guides at the same time
until they bottom out.
4.12
While holding wires in wire guides, terminate
rocker with thumb (lower rocker all the way).
4.13
Terminate additional voice pairs to lower right
and upper left rockers as required.
4.14
Terminate the DSL customer wire pair at
upper right locker only.
4.15
Assure all rockers are in the down position
and close customer security cover.
5.0 CUSTOMER TELEPHONE WIRE INTEGRITY
TESTING
5.1 Open customer security cover.
5.2 Insert RJ-11 plug into customer test jack to
isolate telco from customer wiring.
5.3 Lift all rockers to the up position.
5.4 Insert customer telephone wire into rocker wire
guides as shown (see Figure 3).
5.5 Terminate rocker (lower rocker all the way).
5.6 Using an ohmmeter, insert probes into test ports
as shown (see Figure 3), and check for continuity.
5.7 Customer wiring is ok if meter does not indicate a
short circuit.
5.8 Repeat test for all four sets of customer telephone
wires. If the customer telephone wire does not
show a meter reading, then it has a break in it.
5.9
Close customer security cover and inform
customer.
6.0 CENTRAL OFFICE SIGNAL TESTING
6.1 Open customer security cover.
6.2 Using a working telephone, insert telephone RJ-
11 plug into customer test jack (see Figure 4).
6.3 Wait a few seconds, lift receiver, and listen for
tone.
6.4 If tone is not present, then contact central office
service provider.
6.5 If dial tone is present, then a problem exists in the
customer telephone wires.
Figure 2
Figure 3
Figure 4