Tii IF100PFNOPNST1 User Manual
Page 2
Installation
Use and location selection
Fixed indoor BET is intended for indoor use and
should be located:
1. Inside a building or other suitable shelter
2. Mount on the suitable vertical surface that is
firm and screw holding power is adequate.
3. Where easily accessible and where
maintenance will not block a passageway.
4. Where there is no risk of severe moisture.
5. With adequate clearance from electric light
fixtures, equipment and power circuits and
where there is no risk of damage by moving
machinery, doors etc.
6. Near a suitable earth ground.
Protector Modules
BET will accept five pin protector modules. Protector
modules must be listed for primary protection per
UL497 in order to maintain the UL listing of the BET.
The BET and Protector Modules shall be installed and
connected to earth ground IAW the instructions
contained herein and the applicable requirements of
the National Electric Code, ANSI/NFPA-70, Article 800
and any applicable local codes.
CAUTION
Risk of Electrical Shock - The BET is not to be
used without associated protector modules.
Installation
1. Align unit in desired location on a vertical
mounting surface.
2. Affix unit securely with four # 10 wood screws
supplied with the BET
Figure 2
3. Insert the OSP cable through the cable
grommet to fit snuggly around the cable.
Terminate a connection with the wires in splice
chamber using MS² or equivalent. To ease
termination of the MS² connector. BET panels
are equipped with MS² connector brackets.
Figure 3
4. Connect 6 AWG ground to the shielding of the
OSP cable using a (user supplied) clamp.
Figure 4
5. Attached 6 AWG solid copper ground wire to
the ground bar.
6. Install the tip and ring wires of the customer
premises to the appropriate IDC rockers.
7. Plug the 5 pin protector modules into the
corresponding protection fields.
BET units can be vertically stacked. Maximum of 5 100
pair cables cab be passed through the BET.