beautypg.com

System setup mode (gpt mode) – TeeJet 834-P Sprayer Control User Manual

Page 11

background image

TECHNOLOGIES

834-P Sprayer Control

11 98-70028-R0

System Setup Mode (GPT mode)

The System Setup Mode contains the programming steps that customize the controller to the
sprayer or sprayer components. These include calibration steps and parameters that, once
programmed, are not likely to change.

To enter the System Setup Mode:

First be sure that the console is ON (if not turn it on by pressing the key and wait
until the normal display is visible).

Ensure the Master boom switch is OFF.

Then press and hold the key for 3 seconds to enter the Program Mode.

O

PERATING

M

ODE

The 834-P can operate in either of two modes. They
are GPT (gallons per ton), used for pre-wetting
applications, or GPA (gallons per acre)used for
agricultural or anti-icing applications.

Use the

+

or

keys to adjust this value. Once

the correct mode has been selected, press
the key to advance to the next step. If
operating in GPA mode, skip ahead to page 14.

M

INIMUM

RPM

The 834-P can be set to automatically switch off the
flow of liquid when the salt/sand auger shaft slows
below a minimum speed. This feature prevents
liquid from being applied when the salt/sand
spreader is switched off.

Use the

+

or

keys to adjust this value to the

shaft RPM below which the pre-wetting spray should
be switched off.

tip

select

GPA

GPT

SPEED

RPM

PSI

On

Inch

lbs/rot

PROGRAM MODE push 3 sec.

GPT

Gal/min

@40 psi

P/300ft

P/rot

MPH
RPM

min

0.0

tip

select

GPA

GPT

SPEED

RPM

PSI

On

Inch

lbs/rot

PROGRAM MODE push 3 sec.

Gal/min

@40 psi

P/300ft

P/rot

MPH
RPM

min