System setup mode (gpt mode) – TeeJet 834-P Sprayer Control User Manual
Page 11
TECHNOLOGIES
834-P Sprayer Control
11 98-70028-R0
System Setup Mode (GPT mode)
The System Setup Mode contains the programming steps that customize the controller to the
sprayer or sprayer components. These include calibration steps and parameters that, once
programmed, are not likely to change.
To enter the System Setup Mode:
First be sure that the console is ON (if not turn it on by pressing the key and wait
until the normal display is visible).
Ensure the Master boom switch is OFF.
Then press and hold the key for 3 seconds to enter the Program Mode.
O
PERATING
M
ODE
The 834-P can operate in either of two modes. They
are GPT (gallons per ton), used for pre-wetting
applications, or GPA (gallons per acre)used for
agricultural or anti-icing applications.
Use the
+
or
keys to adjust this value. Once
the correct mode has been selected, press
the key to advance to the next step. If
operating in GPA mode, skip ahead to page 14.
M
INIMUM
RPM
The 834-P can be set to automatically switch off the
flow of liquid when the salt/sand auger shaft slows
below a minimum speed. This feature prevents
liquid from being applied when the salt/sand
spreader is switched off.
Use the
+
or
keys to adjust this value to the
shaft RPM below which the pre-wetting spray should
be switched off.
tip
select
GPA
GPT
SPEED
RPM
PSI
On
Inch
lbs/rot
PROGRAM MODE push 3 sec.
GPT
Gal/min
@40 psi
P/300ft
P/rot
MPH
RPM
min
0.0
tip
select
GPA
GPT
SPEED
RPM
PSI
On
Inch
lbs/rot
PROGRAM MODE push 3 sec.
Gal/min
@40 psi
P/300ft
P/rot
MPH
RPM
min