Username/password commands, System commands – Solvline SG-2xxx Series User Manual
Page 61

SerialGate User Guide
61
Commands
Default
Description
def port x keepalive
<0 ~ 65535>
0
After a certain amount of time passes without any
communication after the socket connection between the
given serial port and the server is established, automatically
disconnect the socket connection.
def port x latency
0
This needs to be set when consecutive data from the given
serial port needs to be transmitted to socket at once.
def port x login
Disable
When the Operation Mode is set to TCP Server, ask for the
username and password when the client tries to connect.
def port x loginname
None
When the Operation Mode is set to TCP Server, set the
username to ask for(Max 8 bytes)
def port x loginpass
None
When the Operation Mode is set as TCP Server, set the
password to ask for( Max 8 bytes)
def port x
termination
Disable
Set termination for each port. (for SG-1160 model only)
Username/Password Commands
Configure username and password for Web Manager/Telnet/FTP.
Commands
Default
Descriptions
def username
serialgate
Set username to use in the web manager, Telnet, or FTP.
16 characters at maximum.
def password
99999999
Set password to use in the web manager, Telnet, or FTP.
16 characters at maximum.
System Commands
Commands
Descriptions
def default
Restore all settings to factory default. Requires reboot for changes to
take effect.
def apply
Save and apply changed settings.
Reboot
Reboots SerialGate.