Firmware update using ftp – Solvline SG-1160 User Manual
Page 64
SerialGate User Guide
64
Firmware Update using FTP
A user can upload firmware using web browser, FTP, and etc.
1) Connect to SerialGate with FTP, using correct username and password. (Default: serialgate,
99999999)
2) Issue a command
‘bi’ for binary file transfer mode. Optionally use ‘hash’ to see the data transfer
mark.
3) Issue
‘put’ command to upload the firmware file.
4) After getting a
‘Transfer complete’ message, issue a command ‘bye’ to disconnect. Now we are
ready to update the firmware.
Microsoft Windows XP [Version 5.1.2600]
(C) Copyright 1985-2001 Microsoft Corp.
C:\Documents and Settings\xxx>
ftp 192.168.0.223
Connected to 192.168.0.223
220 Operation successful
User(192.168.0.223:(none)): serialgate Default
Password:99999999 Default
ftp>bi
ftp>ha
ftp>put c:\sg.bin choose the firmware and upload
200 Operation successful
150 Ok to send data
######################################################################
######################################################################
#######################################################
226 Operation successful
ftp: 2214352 bytes sent in 0.86Seconds 2577.83bytes/sec.
ftp>bye
5) Connect to SerialGate via Telnet, using correct username and password. (Default: eddy,
99999999)
6) After the login, you are already at the default directory where the firmware resides. Update can
start right away.
7) Issue a command ls to make sure firmware files are both successfully uploaded.
8) Use
‘upgrade’ command to write this file into the flash memory in SerialGate. The upgrade