INDIRECT FIRED WATER TANK

IV INSTALLATION/PIPING (cont’d)

PIPING

2. Domestic Water

a. Cold Water In. Install brass tee and drain valve (not
provided). Install shutoff valve between water supply

and cold water inlet for ease of service as shown in the

exhibit below.

b. Standard Domestic Hot Water Out. A heat trap will
improve energy efficiency by reducing piping heat loss.

Thermostatic Mixing Valve

At times a thermostatic mixing valve may be recommended

or required. The thermostatic mixing valve

blends domestic cold water with hot water exiting from

the heater, to yield a more constant desired temperature.

Risk of scalding is not eliminated with the use of a

thermostatic mixing valve. Refer to literature provided

by valve manufacturers for recommended installation.

Expansion Tank

When a back flow device or no return valve is installed in

the system a Thermal Expansion Tank designed for use

with potable water will be required. Locate the expansion

tank on the domestic cold water line near the heater

between the back flow device or no return valve and the

heater (see piping diagrams). Refer to the Thermal expansion

Tank manufacturer literature for sizing.

Vacuum Breaker

Slant/Fin recommends that a vacuum breaker be installed on

the domestic piping to the heater. The vacuum breaker

protects the heater in the event that tank pressure falls

below atmospheric pressure.

Temperature & Pressure Relief Valve( T & P)

A T & P is required on all heaters. Install a

T & P valve (long element type) into the separate tapping

designated for the T & P.

Install temperature and pressure protective equipment

required by local codes, but no less than a combination

temperature and pressure relief valve certified as meeting

the requirements for relief Valve and Automatic Shutoff

Devices for Hot Water systems, ANSI Z21.22, by a nationally

recognized testing laboratory that maintains periodic

inspection of listed equipment or materials.

The valve must be oriented, provided with tubing or

otherwise installed so that discharge can exit only within

six (6) inches above, or at any distance below, the structural

floor, and cannot contact any electrical part. The

valve must be piped to an area where discharge will not

cause personal injury or damage the surrounding area.

WARNING!

INSTALL A T & P WITH A RATED CAPACITY THAT IS

EQUAL TO OR GREATER THAN THE OUTPUT OF THE

ENERGY SOURCE.

REMOVAL OF THE T & P, OR FAILURE TO REPLACE

TEMPERATURE- PRESSURE RELIEF VALVE, WILL

RELEASE THE MANUFACTURER FROM ANY CLAIM

WHICH MIGHT RESULT FROM EXCESSIVE

TEMPERATURES AND PRESSURES.