beautypg.com

Notice, Danger, I safety – Slant/Fin HWT-120 User Manual

Page 2

background image

NOTICE

I SAFETY

The warranty on this water heater is in effect only when the

water heater is installed and operated in accordance with

these instructions. The manufacturer of this water heater will

not be liable for any injury or property damage resulting

from failure to comply with these instructions.

WARNING! This water heater must be installed strictly in
accordance with the instructions enclosed, and local electri-

cal, fuel and building codes. It is possible that connections to

the water heater, or the water heater itself may develop

leaks. IT IS THEREFORE IMPERATIVE that the water

heater be installed so that any leakage of the tank or related

water piping is directed to an adequate drain in such a way

that it cannot damage the building, furniture, carpeting, adja-

cent areas, lower floors of the structure or other property

subject to water damage. This is particularly important if the

water heater is installed in a multi-story building, on finished

flooring or carpeted surfaces. SLANT/FIN CORP. CANNOT

BE HELD LIABLE for damage caused by water from the

water heater, pressure relief valve, or related fittings. Closets

without drains and carpeted areas are examples of unsuit-

able locations for any water heater. Select a location as cen-

tralized within the piping system as possible. The heater

should be located in an area not subject to freezing temper-

atures at any time. It is recommended that a suitable drain

pan be installed under the water heater. This pan shall be a

minimum of 50mm (2 in.) deep and have a diameter that is

a minimum of 50mm (2 in.) greater than the diameter of the

water heater. Suitable piping shall connect the drain pan to

a properly operating floor drain.

Relief Valve Requirements

Caution: To reduce the risk of excessive pressures and
temperatures in this water heater, install temperature

and pressure protective equipment required by local

codes. It should be no less than a combination temperature

and pressure relief valve certified by a nationally

recognized testing laboratory that maintains periodic

inspection of production of listed equipment or materials,

as meeting the latest edition of ANSI Z21.22:

Requirements for Relief Valves and Automatic Gas

Shut-off Devices for Hot Water Supply Systems. This

valve must be marked with a maximum set pressure not

to exceed the marked MAXIMUM working pressure of the

water heater (150 PSI). Install the valve into an opening

provided and marked for this purpose in the water

heater, and orient it or provide tubing so that any

discharge from the valve will exit only within 6 inches

above, or any distance below the structural floor and

cannot contact any live electrical part. The discharge

opening must not be blocked or reduced in size under

any circumstances. The end of the relief pipe opening

should terminate near a floor drain or other suitable

location not subject to blocking or freezing. DO NOT

thread, plug or cap the relief pipe opening.

2

INDIRECT FIRED WATER TANK

Water temperatures over 125ºF can cause severe burns instantly,

or death from scalds.

Children, disabled, and elderly are at the highest risk of being scalded.

See instruction manual before setting temperature at water heater.

Feel water before bathing or showering.

Temperature limiting valves are available, see manual.

The Indirect-fired water heater is deemed to be used in a "commercial setting" if at any time the unit is oper-

ated at a temperature over 150ºF. Refer to warranty for additional information.

DANGER

r

!

r

!

HOT

BURN

This manual is related to the following products: