V WIRING (cont’d)

TANKLESS COIL BOILER APPLICATION - PRIORITY FIGURE 3

10

INDIRECT FIRED WATER TANK

ZO ZON

ZO

INDIRECT TANK
TEMP CONTROL

I

INDIRECT

TANK

CIRCULATOR

I

Operation: When any thermostat calls for heat, the
boiler is given a signal to start. The appropriate

circulator is energized only when the boiler temper-

ature is above the set low limit.

Priority Operation: When zone 6 is switched to
the priority setting and is actuated, all other zones

will stop operation until zone 6 is satisfied. When

zone 6 is not switched to priority, all zones will oper-

ate independently.

Jumper Placement:

REMOVE the jumper

between terminals ZC and ZR. Connect terminal

ZC to ZC terminal on the aquastat control. Connect

terminal ZR to ZR terminal on the aquastat control.

Confirm polarity is consistent between boiler aqua-

stat and switching relay.

Power Input: Connect 120 volt as power
input to terminals N and H. Neutral wire to

terminal N. Hot wire to terminal H.