SeaLand 4400 Series Toilet Installation User Manual
Page 10
10
Installation
Dometic 4300/4400 Series Toilets
5.2
Wall switch installation – 4400 series toilet
1 . Select a location for the switch . 8 feet of cable (2 .4 m) is
provided . More wire may be required, depending on how far the
switch is located from the toilet .
2 . Cut an opening 1-1/4 in . wide x 1-5/8 in . high (fig .
25
,
page 11) .
3 . If installing the switch in a shallow wall, you may need to use
the spacer between the wall and the switch assembly cover
to allow space for the wire connectors . If so, route the cable
through the spacer before proceeding to the next step .
4 . Route the 3-conductor cable through wall cut-out and on to toilet . Cable can be routed through
hole with water supply line and power wires (fig .
23
) . Leave a minimum of 12 inches (305 mm)
of cable to allow easy wiring at toilet .
5 . Fasten the switch assembly to the wall with the #6x1 in . screws (included), making sure to install
with the label “THIS SIDE UP” on top (fig .
24
) . Otherwise, the “Flush” and “Add Water” func-
tions will be reversed .
6 . Snap cover onto switch assembly to complete switch installation on wall .
7 . WITH THE ELECTRICAL POWER OFF, connect the red, black and white wires from the switch
to the red, black and white wires of the Remote Flush Cable from the toilet (fig .
23
) .
23
24