6
3.2
“Full tank” indicator
When	connected	to	a	“full	tank”	sensor	(see	wiring	schematics,	pp.	8-9),	a	steady	illuminated	red	light	
can	indicate	that	the	holding	tank	is	full.	(fig.	
3
B, page 2).The VacuFlush toilet should not be
operated until the hoiding tank is emptied and the green light turns on .
3.3
Vacuum system control
During	the	night	or	other	extended	periods	of	non-use,	the	toilet	system’s	vacuum	level	may	slowly	
dissipate	and	cause	the	vacuum	pump	to	operate.		To	avoid	this,	switch	the	VacuFlush	system	power	to	
“off”	(fig.	
3
C, page 2) .
3.4 Features
Continuous vacuum level monitoring.		Indicates	when	VacuFlush	toilet	is	ready	to	flush.
Vacuum system protection. Magnetic circuit breaker protects pump from damage .
Power indicator for toilet system. Indicates when toilet system power is off or loss of electrical 
power .
12 or 24 V DC operation.
4
Components
(fig.
1
, page 2)
Ref
Description
1
DVS02 panel cover
2
Mounting frame
3
#6 fastener
4
Circuit housing
5 Specifications
5.1 Materials
Panel frame and mounting frame: ABS
Circuit housing: High-density polyethylene
Panel surface: Polycarbonate resin
5.2 Electrical
Current and wattage per indicator light
12 V DC
24 V DC
Amps
0.012 - 0.016
0.012 - 0.016
Watts
0.15 - 0.22
0.29 - 0.45
Circuit breaker – magnetic, manual reset
SIZE
F.L. amps
Trip amps
10 amps
10
13 .5
5 amps
5
6 .75
Specifications subject to change without notice .
Intended use
Dometic Vacuum Status Control Panel
Note 
Be	sure	circuit	breaker	size	of	DVS02	
panel	matches	VacuFlush	system	power	
requirements . Refer to wiring 
schematics, pp . 8-9 .