Components, Specifications, 4components – SeaLand DVS02 Vacuum Status Control User Manual
Page 6: 5 specifications
6
3.2
“Full tank” indicator
When connected to a “full tank” sensor (see wiring schematics, pp. 8-9), a steady illuminated red light
can indicate that the holding tank is full. (fig.
3
B, page 2).The VacuFlush toilet should not be
operated until the hoiding tank is emptied and the green light turns on .
3.3
Vacuum system control
During the night or other extended periods of non-use, the toilet system’s vacuum level may slowly
dissipate and cause the vacuum pump to operate. To avoid this, switch the VacuFlush system power to
“off” (fig.
3
C, page 2) .
3.4 Features
Continuous vacuum level monitoring. Indicates when VacuFlush toilet is ready to flush.
Vacuum system protection. Magnetic circuit breaker protects pump from damage .
Power indicator for toilet system. Indicates when toilet system power is off or loss of electrical
power .
12 or 24 V DC operation.
4
Components
(fig.
1
, page 2)
Ref
Description
1
DVS02 panel cover
2
Mounting frame
3
#6 fastener
4
Circuit housing
5 Specifications
5.1 Materials
Panel frame and mounting frame: ABS
Circuit housing: High-density polyethylene
Panel surface: Polycarbonate resin
5.2 Electrical
Current and wattage per indicator light
12 V DC
24 V DC
Amps
0.012 - 0.016
0.012 - 0.016
Watts
0.15 - 0.22
0.29 - 0.45
Circuit breaker – magnetic, manual reset
SIZE
F.L. amps
Trip amps
10 amps
10
13 .5
5 amps
5
6 .75
Specifications subject to change without notice .
Intended use
Dometic Vacuum Status Control Panel
Note
Be sure circuit breaker size of DVS02
panel matches VacuFlush system power
requirements . Refer to wiring
schematics, pp . 8-9 .