beautypg.com

NORAC UC4.5-BC Operator Manual User Manual

Page 34

background image


30

ACTIVE ROLL SYSTEM:

Perform the Quick Install for the standard system as previously described.

Navigate to the "Roll ?" menu prompt in the SETUP (

) menu. Press

and then change

it to "Roll OnA" using the

buttons. Press

to confirm.

Navigate to the "Roll ?" menu prompt in the SENSOR DISPLAY menu. Select the
appropriate sensor serial number for the BF (boom frame) and IF (intermediate frame)
sensor. Press

, and then set the "IFh" (intermediate frame height) and "BFh" (boom frame

height) to zero using the

buttons. Press

to confirm.

Perform a ReTune (Section 8.2).

BFh 0

IFh 0

Roll OnA