NORAC UC4.5-BC Operator Manual User Manual
Page 20
16
Note: Some sprayer types do not support a wiring test or they may support a different style of test. If
there are no messages displayed in this step, simply continue as prompted by the panel.
8.1.5 Sensor Detect
•
Position all boom sections such that the nozzles are 35 inches (90 cm) from the ground.
•
Press
to continue.
Note: If it is not possible to get all the booms set to exactly 35 inches (90 cm), the sensor height can be
adjusted after the install is finished. Refer to Section 8.3.1 for more details.
•
Hold the
button to begin the sensor detect sequence. The
button must be held for
the duration of the procedure. If
is released, simply press and hold again to continue
the procedure.
•
The control panel will automatically move the booms to detect and assign the sensors to
the correct locations.
•
Release the
button to continue.
Switch
Release
Proceed?
Hold
Auto
Until
“Done”
Height
35 inch
Booms at
Level
Left Dn
Press
Rght Up
Press
Rght Dn
Press
Main Up
Press
Main Dn
Press