30
Figure 38: Cable Configurations: C10, C11, C14 and C15
2. Connect R10 and P4 on the UC4+
power cable (C10) to the mating
connectors on the UC4+ Control Panel
(E01) (Figure 38).
Ensure the UC4+ Control
Panel’s power is OFF for the
remaining installation.
(Bottom of switch pressed IN).
3. Plug the 3-pin connector on C14 into
the cab’s power bar.
4. Find a suitable location to mount the
hand control (C15) in the cab where it
is easily accessible.
The cable on C15 must be able to
reach to the mating cable (P16B)
on the UC4+ power cable.
5. Attach connector R16B on the hand
control cable (C15) to connector P16B
on the UC4+ power cable (C15).
6. Route the free ends of C10 along the
side of the cab post and under the floor
mat.
Figure 39: Hole under Floor Mat
7. Route the free end (R16) of C10 out
the hole under the floor mat (Figure
39).
The hole in the floor may be
covered by a plate, or a grommet
may be installed in the hole. They
can be reinstalled after the wiring
is complete. NORAC supplies a
grommet for the hole if one does
not exist.
The hold in the floor may be too
small for the connector. In this
situation the cable can be routed
out the back of the cab through
an opening close to the bottom
of the rear, right window (Figure
40).