Ctx charge – Muchmore Cell Master Platinum (PT-CTXC) User Manual
Page 24
10.CTX CHARGE
E 9
CTX-chage does not allow chaging set up
during charging.
How to use CTX-charge as Peak charge with
repeak charge.
1. Set capacity 0000 at 1/3,2/3 steps
2. Set 3/3 charge step.
3. Set repeak (Rn to 3times)
4. Start to charge
5. The CM will skip 1/3,2/3steps, then
charge with 3/3step.
6. After charge termination, the CM will
repeak as programmed.
3/3 step’s set up is shown.
1/3 step charging.
Peak locked(Key mark is shown)
2/3step charging.
Peak locked(Key mark is shown)
3/3step charging.
Peak detection in on now(Key mark is dissapeared)
If you start CTX-CHG with key+3sec, double keys
will be appeared. Each means
Peak locked 1/3-2/3
Long lock out by time
(settable at User setup
mode)
After charging termination, now delaying 5min
waiting for repeak.
Trickle charging is proceeding.(Ty)
Repeaking with 3/3step (4A, 03mV)
RE1 means First repeak.
RE2 second,
RE3 Third.
Peak voltage
Temp. at charge
termination and
charged time are
shown in turn.
All charging procedure finished.
You can check charged data with Increment or
decrement key.
Less capacity is the capacity at peak voltage
More capacity is the capacity at charging termination.
Forward key will return to initial display of CTX-charge.
Trickle charging is proceeding.(Ty)
.CTX CHG 1
.CTX CHG 2
4.0A 03 00:00
SET 3800 7.750
4.0A 03 00:00
SET 3800 8.566
7.0A 00:27
1/3 0055 8.780
6.0A 20:10
2/3 2305 8.867
4.0A 03 28:50
3/3 3000 8.934
4.0A 03 01:37
RE1 3680 9.111
DLY 3586 8.785
PEAK CUT
01:16
00:03
TRK 3763 8.805
PEAK CUT
52.9
DAT 3744 8.805
9.142