Peak charge-set up – Muchmore Cell Master Platinum (PT-CTXC) User Manual
Page 20
6.PEAK CHARGE-set up
KEY OPERATION
OPTIONAL PART
E 5
CELL NUMBER
6
n
n
Tn
Backward
Set values
Forward
+1second back to Main menu
Choose number of cells.
This setup will guarantee the CM’s right
operation.
Fan stand(Part #MR-12F) that attached on the
CM’s right side will be controlled by this set
up during charge.
Determine temperature terminating of charge.
Make sure Thermo-sensor always keeps good
contact on the battery’s surface.
We recommend, in summer set to 42-48deg.C,
In winter, 40-42deg.C which works fine but will
defend on your location.
If you select Trickle charge “Y(yes)”, the CM
will charge your battery at a very low
rate(0.1A) after charge.
This prevents voltage’s drop after charge.
Use trickle charge mode only for NiCD.
FAN START TEMP
6
n
n
Tn
CHG STOP TEMP
6
n
n
Tn
TRICKLE CHARGE
6
n
n
Tn
.PEAK CHG 1
.PEAK CHG 2
.PEAK CHG 1
.PEAK CHG 2
Page 6 PEAK CHG 1
LOW 0000 18.0 C
4.0s 03 00:00
CHG 0020 8.204
4.0A 03 00:02
배터리의 온도가 CHG START TEMP
설정값보다 낮을때의 디스플레이 예
키를 누르면 온도를 무시하고 충전에
들어갑니다.
배터리워머를 CM에 연결하고 목표온도에
도달하면 충전이 자동으로 시작됩니다.
MR-12FB 12V Cooling fan stand blue
MR-12FK 12V Cooling fan stand black
MR-12FP 12V Cooling fan stand purple
MM-WTB Warming tray blue
MM-WTK Warming tray black
MM-WTP Warming tray purple