7.PEAK CHARGE - 1

KEY OPERATION

E 6

SET 0000 13.802

0.0A 03 00:00

SET:set up display

DLY:Delaying

CHG:charging

ERR:Error

*CHK CLIP* Check alligator clips

*OVER VOT* Over voltage error occured. The

voltage of charging battery is higher than the

voltage of power supply. Decrease charging amp

or increase voltage of power supply.

*OVERHEAT* The CM is very hot.
Do not block the air flow around slots or the fan

inlet in the back of the case. This could cause

excessive heat build up and may short out the
output circuit FETs which would void warranty.
Blow out dirt in the fan and heatsink area

occasionally. Otherwise there may be excessive

heat build up that could cause the unit to fail.

:Power supply voltage
:Voltage at output connectors.
:Temperature at output thermo sensor

Auto start Timer:

This convenient feature lets you preselect when

you want to start the CM for a charge session:

adjustable from 0 to 18hours.

Backward

Capacity, Peak sesitivity, Auto

start timer value setting
Forward, Charge start

+1second:Charge start

+2seconds:Long lockout charge

start

Delta peak value setting(Threshold setting)

03 means 3mV(0.003V). The delta peak value entered is the drop in

millivolts that the CM looks for to determine that battery pack has peaked.

This is adjustable from 03~99mV/pack. To adjust,push the

buttons. If you set up high delta peak value, the CM will charge longer

time. We recommend to start charge with 03mV for all batteries at the

beginning. Under certain conditions, a battery pack or cell can exhibit a

false peak. Under these circumstances, it peaks before it is charged, and

the result is that battery pack or cell does not receive a full charge.

False peaks can be caused by several things. Batteries that have been fully

discharged can false peak for several minutes. Use long lockout to alleviate

this problem. Another cause is using alligator clips on solid leads. This can

produce a poor connection that can’t handle the charge current. It is best

to clip onto braided wire or multi-stranded wire where more area is

contacted by alligator clips.

LONG LOCKOUT CHARGE(can be used PEAK, CTX CHG, CYCLE)

Set long lockout charge time(1~30min) at USER SETUP(page4)

Press and hold key for 2seconds. If long lock out charge acts,

mark will be shown instead of delta peak value.

ZERO DELTA PEAK(Set delta peak value at 00(0mV))

The CM has Zero delta peak charging cut off system which can cut off

charge at the peak voltage if the peak voltage stays for 7seconds(If this

condition is not satisfied, the CM will cut off by 3mV). For preventing from

false zero delta peak before it is charged, zero delta peak will act after

70% charge of set capacity. (See graph2)

20minutes long lockout

Charging current(Ampere)

For battery’s safety and life time, always charge

under 4A for Sub-C type,

2A for AA, AAA type batteries.

Volt

Long lock out

Peak detecting

Time

20min.

0min.

CAPACITY(mAh) can be limited .
Set 5~10% higher than battery’s
capacity.

Ex: GP3300 => 3600

Example:
Capacity:3600mAh
ZERO DELTA PEAK

Volt

Capacity

0

3600(100%)

2520(70%)

3mV

Zero delta peak acts

Graph 1

Graph 2