Protecting Against Electrostatic Discharge
Static electricity can harm delicate components on
the AD-R96 board. To prevent static damage,
discharge static electricity from your body before you
touch any electronic components. You can do so by
touching an unpainted metal surface on the HV-3R’s
chassis.
Unplug the HV-3R’s AC power cord before
inserting or removing the AD-R96 board
Clocks - the AD-R96 should have only one clock
source. If running with the internal clock, make sure
SW4 is in the INT position and no external clock is
connected.
Sync Signals on the BNC connectors should
conform to the AES-3id specification. AES-3,
through an XLR-to-BNC transformer (Neutrik
S/PDIF works, but is not specified.
Sample Rate kHz
SW2
SW1
44.1*
X1
44
48
X1
48
88.2
X2
44
96
X2
48
Clock Source
SW4
Internal
INT
External*
EXT
*The arrows point to the
default jumper positions.
Clock Input
J2
Word Clock*
on
AES
off
Clock Termination
J3
75 ohms*
on
Unterminated
off
Clock Output
J4
J5
Word Clock*
2,3
2,3
AES
1,2
1,2