page 31 of 40 rev 1.4.2 041409 Millennia Media HV-3R

AD-R96 (Option) User Guide


Protecting Against Electrostatic Discharge
Static electricity can harm delicate components on
the AD-R96 board. To prevent static damage,
discharge static electricity from your body before you
touch any electronic components. You can do so by
touching an unpainted metal surface on the HV-3R’s
chassis.

Unplug the HV-3R’s AC power cord before
inserting or removing the AD-R96 board

Clocks - the AD-R96 should have only one clock
source. If running with the internal clock, make sure
SW4 is in the INT position and no external clock is
connected.

Sync Signals on the BNC connectors should
conform to the AES-3id specification. AES-3,
through an XLR-to-BNC transformer (Neutrik
NADITBNC-F or equivalent) will work fine.
S/PDIF works, but is not specified.


Sample Rate kHz

SW2

SW1

44.1*

X1

44

48

X1

48

88.2

X2

44

96

X2

48

Clock Source

SW4

Internal

INT

External*

EXT


*The arrows point to the
default jumper positions.

Clock Input

J2

Word Clock*

on

AES

off

Clock Termination

J3

75 ohms*

on

Unterminated

off

Clock Output

J4

J5

Word Clock*

2,3

2,3

AES

1,2

1,2