revised 121808
Protecting Against Electrostatic Discharge
Static electricity can harm delicate components on
the AD-D96 board. To prevent static damage,
discharge static electricity from your body before you
touch any electronic components. You can do so by
touching an unpainted metal surface on the HV-3D’s
chassis.
Unplug the HV-3D’s AC power cord before
removing the top cover and changing settings
on the AD-D96 board.
Clocks - the AD-D96 should have only one clock
source. If running with the internal clock, make sure
SW2 is in the INT position and no external clock is
connected.
Sync Signals on the BNC connectors should
conform to the AES-3id specification. AES-3,
through an XLR-to-BNC transformer (Neutrik
S/PDIF works, but is not specified.
Sample Rate kHz
Rear Panel
44.1* X1
44
48 X1
48
88.2 X2
44
96 X2
48
Clock Source
SW2
Internal INT
External* EXT
*The arrows point to the
default jumper positions.
Clock Input
J12
Word Clock*
on
AES off
Clock Termination J14
110 ohms*
on
Unterminated off
Clock Output
J15 J17
Word Clock*
2,3
2,3
AES 1,2
1,2