www.mfdigital.com

USB SD Platform 5000 series

for 30 seconds, so when the system detects that all the flash cards have been
removed and no new cards have been inserted after 30 seconds the LCD will display:


Press OK to exit the current Asynchronous copy or press ESC to keep the unit
operating in the current Asynchronous copy.

3.5

Ignore Size


The purpose of this function is to set the flash card tolerance between the source
and target memory capacity.

The default setting is “Don’t Care” and this means there is no limit of tolerance
between the source and target. If you require the source and target flash cards to be
limited to a certain capacity tolerance then you can set the percentage of the
tolerance. For example if your source device has a capacity of 1919MB, that means
the acceptable target devices’ capacity will be limited to between 1976MB to
1861MB.

Note: If the capacity difference between the source and target is larger
than the tolerance setting then when you start to copy Red LED will be lit
to indicate there is an error. You will then see a “Fail” message and you
can press the

buttons to check the status of each flash card that is

currently in the Asynchronous Copying process.


Differences in Source and Target capacity

If Source capacity is smaller than the target, for example 1GB to 2GB:


Example: A. Source B. Target

1GB

2GB









Note: When there is a big difference in the target and source’s capacity
such as 1GB to 4GB, there is a possibility to cause error to the target’s
capacity and format. It is strongly recommended that the capacity of the
target and source are within a close range.


Copy OK

.

FAT
table

Warning: The 2GB target device will
become 1GB when it is read on a PC.
You can only restore its real capacity by
re-formatting the device.

FAT