73M1866B/73M1966B Implementer’s Guide

Rev. 1.3

25

6.2 PCLKDT Interrupt

The triggering of the PCLKDT interrupt indicates that the device has detected a PCLK error. When found,
it can be assumed that there is a problem with the PCLK. If the error is temporary, the error can be
cleared by resetting the PLL. If the error is due to an external clock failure this error will not clear.

0x05

ENGPIO7 ENGPIO6 ENGPIO5 ENPCLKDT ENAPOL

ENDET

ENSYNL ENRGDT

Write

X

X

X

1

1

X

X

X


Set the ENPCLKDT bit in Register 0x05 to enable the PCLKDT interrupt.

Begin

1. If PCLKDT =1 (IntSrc = xxx1_xxxx) then goto PLL Recovery Process (see

Section 3.1.2 PCLK Clock

Recovery and PLL Lock Detection

).

End

6.3 DET Interrupt

The triggering of the DET interrupt indicates that the device has detected one of several line condition
errors. When found, it can be assumed that there is a problem with the line status. The general
corrective action is for the line side device to go on hook. These interrupts are only valid when the device
is in an off-hook condition.

0x05

ENGPIO7 ENGPIO6 ENGPIO5 ENPCLKDT ENAPOL

ENDET

ENSYNL ENRGDT

Write

X

X

X

X

1

1

X

X

0x12

OFH

ENDC

ENAC

ENSHL

ENLVD

ENFEL

ENDT

ENNOM

Write

1

1

1

x

x

1

1

x

0x13

DCIV1

DCIV0

ILM

RSVD

PLDM

OVDTH

IDISPD

Res

Write

X

X

0

0

0

1/0

0

0

0x14

TXBST

DAA1

DAA0

Res

RXBST

RLPNH

RXG1

RXG0

Write

X

X

X

0

X

X

X

X

0x15

ENOLD

DISNTR

Res

CIDM

THEN

ENUVD

ENOVD

ENOID

Write

1

0

0

0

1

1

1

1

0x1E

ILMON

UVDET

OVDET

OIDET

OLDET

SLLS

Res

Res

Read

X

?

?

?

?

X

X

X


Set the ENDET bit in Register 0x05 to enable the DET interrupt.

Begin

1. If DET = 1 (IntSrc = xxxx_x1xx).

2. Read RG1E

3. If OVDET = 1, report condition to user and put device on hook.

4. If OIDET = 1, report condition to user and put device on hook.

5. If OLDET = 1, report condition to user and put device on hook.

6. If UVDET = 1, report condition to user and put device on hook.

End