beautypg.com

4 on-hook procedures, On-hook procedures, Cid mode – Maxim Integrated 73M1866B/73M1966B Implementers Guide User Manual

Page 17

background image

UG_1x66B_016

73M1866B/73M1966B Implementer’s Guide

Rev. 1.3

17

4 On-Hook Procedures

The on-hook procedures described in this section include:

CID Mode
Off-Hook Request
Ring Detection and Line Voltage Reversal
Line-in-use and Loss of Battery Feed

4.1 CID Mode

It is possible (while on hook) to allow the RGP/RGN input, which is AC coupled to the line through high
voltage capacitors, to be transmitted on the PCM bus. This allows the host to listen for Caller ID
information without going off hook.

The registers used in this procedure are:

0x14

TXBST

DAA1

DAA0

Res

RXBST

RLPNH

RXG1

RXG0

Write

X

X

X

X

1

X

X

X

0x15

ENOLD

DISNTR

Res

CIDM

THEN

ENUVD

ENOVD

ENOID

Write

X

X

1

1

X

X

X

X


Begin

1. Set RXBST = 1 (Write RG14 = xxxx1xxx).

2. Set CHPSEN = 1, CIDM = 1 (write RG15 = xx11_xxxx).

End

CID Mode

RXBST =1

CHPSEN =1

CIDM =1

End