beautypg.com

Figure 35 – Maxim Integrated MAX11300PMB1 Peripheral Module and Munich (USB2PMB1) Adapter Board User Manual

Page 33

background image

MAX11300PMB1 Peripheral Module and Munich (USB2PMB1) Adapter Board Quick Start Guide

Figure 35. A Potentiometer Is Connected to Ports 4, 14, and GND

3. In the drop-down menu on the top right, select P13_ADC_0V>+10V and click the

Get plot box button. Another plot window opens for ADC on P13. Observe PWM
signal in the ADC plot window. Adjust the pulse width by turning the
potentiometer to the low and high positions and observe the width of the PWM
waveform as shown in

Figure 36

and

Figure 37

.


Note that the input of the level translator can handle up to 5V only. The provided
configuration file is set to deliver a max of 5V in 0V to 10V mode. If other files are
used, be sure not to apply more than 5V at any digital inputs.

33