Т³гж 17 – LABEC AA-17BS User Manual
Page 16

SEA Series Steam Sterilizers
Operation manual
12
7.2 USB module function
Caution:
This function is optional to the demand of customer.
7.2.1Main function:
Storage of printed data of sterilization
Built-in FLASH memorizer
U-disk. Download
7.2.2Basic parameters:
Storage Capacity: 2M bytes
Quantity of printed data could be stored: 2048
Support FAT files
7.2.3Operation instruction:
1.Turn on the power, the mode of USB will start automatically. After self-test, it goes into alert
with the indicator flickering-1 time.
2.After the sterilization cycle ends, the data of sterilizer is sent to the USB mode(The printer
program should be turned on). Indicator will flicker-1 time after the data-transfer finish.
3.During the alert, insert U-disk. The mode indicator will be on, with the U-disk indicator
flickering. And now, it is in the process of data-download. Don't turn the power off or draw
out the USB-disk, which will cause the data lose.
4.After the download finish, USB mode indicator will flicker twice, reminding the user to draw
out the U-disk.
5.During the sterilization cycle, avoid data download, or else, the data will lose.
6.Connect U-disk to computer. You will see files like _2000_, where the downloaded data is kept,
following turns of Year, Month and Day. Easy to print it out.
7.USB mode terror(According to the flickering times of USB mode indicator) and solution:
Times
1
2
3
4
5
6
7
Definition
Solution
Self-test passed
Operation finish
No definition now.
U-disk needs formation
Not enough capacity
U-disk needs formation
USB mode error
Normal
Normal
No definition now.
Format U-disk in FAT files
Delete the files in U-disk
Format U-disk in FAT files