MR51e Terminal Blocks and Jumpers/Jacks:

MR-51E CONNECTIONS

TB1-1

IN1

Input 1

TB1-2

IN1

TB1-3

IN2

Input 2

TB1-4

IN2

TB2-1

IN3

Input 3

TB2-2

IN3

TB2-3

IN4

Input 4

TB2-4

IN4

TB3-1

VO

Reader 1 Power Output

– 12 VDC

TB3-2

LED

Reader 1 LED Output

TB3-3

BZR

Reader 1 Buzzer Output

TB3-4

CLK

Reader 1 CLK/Data 1/TR+

TB3-5

DAT

Reader 1 DAT/Data 0/TR-

TB3-6

GND

Reader 1 Ground

TB4-1

LED

Reader 2 LED Output

TB4-2

BZR

Reader 2 Buzzer Output

TB4-3

CLK

Reader 2 CLK/Data 1 Input

TB4-4

DAT

Reader 2 DAT/Data 0 Input

TB5-1

VO

Auxiliary Power Output

– 12 Vdc

TB5-2

GND

Auxiliary Power Output Ground

TB5-3

VIN

Input Power

– 12 Vdc (from local power supply)

TB5-4

GND

Input Power Ground

TB6-1

NO

Relay K1

– Normally Open Contact

TB6-2

1-C

Relay K1

– Common Contact

TB6-3

NC

Relay K1

– Normally Closed Contact

TB6-4

NO

Relay K2

– Normally Open Contact

TB6-5

2-C

Relay K2

– Common Contact

TB6-6

NC

Relay K2

– Normally Closed Contact

Jumpers:

JUMPER

SET AT

DESCRIPTION

J1

N/A

Factory Use Only

J2

N/A

Factory Use Only

J3

N/A

Factory Use Only

J4

N/A

Factory Use Only

J5

PoE

MR-51E powered from the Ethernet connection

12V

MR-51E powered from an external 12 Vdc power
source connected to TB5-3 (VIN), TB5-4 (GND)

J6

N/A

Ethernet Connection with POE support

J7

N/A

Factory Use Only