1.0
Specifications
Unit Dimensions (nominal)
•
12.09 inches high by 5.60 inches wide by 3.10 inches deep, including hinges
•
(30.71 cm by 14.22 cm by 7.87 cm)
Operating Temperature/Humidity Range
•
-20°F to 140°F (-29°C to 60°C)
•
0% to 90% Relative Humidity, non-condensing
Controller Power Requirements
•
12 VDC @ 1 A
Current Draw
•
maximum current draw 750 mA for a controller
NOTE: If an electronic locking device (such as a magnetic lock, a door strike, or similar device) is to be driven by the
same power supply as the EntraGuard Titanium controller, please ensure the power supply provides enough current to
drive every device connected to that supply plus an adequate safety margin. AC power cannot be used.
NOTE: Isolation of power supplies may be required with high transient situations.
Controller Memory Retention
•
5 year lithium battery back up to support controller RAM and real-time clock
Output Relay Contact Rating
•
1 Amp @ 24 VDC
Input Device Configuration - 3 Inputs
•
Door Sense
normally closed
•
Request to Exit
normally open
•
Global Unlock
normally open (on master only), or
Auxiliary RTE A-Door
normally open
Users Allowed
•
750 tenants maximum
Event Storage Capacity
•
3,640 events