5 connecting a general purpose input, Entraguard, Silver telephone entry control – Keri Systems EntraGuard Silver Quick Start User Manual
Page 9: Quick start guide
EntraGuard
®
Silver Telephone Entry Control
Quick Start Guide
Page 9 of 27
P/N: 01960-001 Rev. D
4.5
Connecting a General Purpose Input
The general-purpose input is used in conjunction with the programmable input/output feature of the Doors access control
software. There are two possible uses for the general-purpose input.
•
the master controller may be configured for either Global Unlock (see Figure 8) or Auxiliary A-door RTE (see Figure
9)
•
the slave unit can only be configured for Auxiliary A-door RTE (see Figure 9)
Make the following connections for a Global Unlock input. (For a master controller only.)
Figure 8: Global Unlock Input Connections
Make the following connections for an Auxiliary RTE A-door input.
Figure 9: Auxiliary A-Door RTE Input Connections