Keri Systems SB-293 User Manual
Page 43
Keri Systems, Inc.
Technical Reference Manual – PXL-250 and SB-293
Revision 5.5
P/N: 01836-004
Page 43
NOTE: All Keri Systems proximity readers can use between 5 and 12 VDC power
while most Wiegand compatible readers use 5 VDC power. Check your reader's
requirements and verify jumper JP4 is set correctly per the Jumper Settings
instructions on page 28. Early revisions of the surface mount PXL-250W mislabeled
the JP4 jumper as JP5. All instructions for the JP4 jumper apply to the jumper
labeled as JP5 (see Figure 9-1 on page 39 for the location of the jumper).
a. Refer to the Wiegand compatible reader’s documentation
for the color of this wire.
Table 4: Single-Line LED Wiegand Compatible
Reader Connections
TB-5/TB-6
Description
Wire Color
Pin 1
Data 0
GREEN
Pin 2
Beeper
refer to reader
a
a. Refer to the Wiegand compatible reader’s
documentation for the color of this wire.
Pin 3
Reader Power
RED
Pin 4
Reader Ground
BLACK
Pin 5
n/a
n/a
Pin 6
Single LED Line refer to reader
a
Pin 7
Data 1
WHITE
Table 5: Dual-Line LED Wiegand Compatible
Reader Connections
TB-5/TB-6
Description
Wire Color
Pin 1
Data 0
GREEN
Pin 2
Beeper
refer to reader
a
Pin 3
Reader Power
RED
Pin 4
Reader Ground
BLACK
Pin 5
Green LED
refer to reader
a
Pin 6
Red LED
refer to reader
a
Pin 7
Data 1
WHITE