beautypg.com

0 cable requirements, 1 rs-232 serial cable, 2 rs-485 network cable – Keri Systems SB-293 User Manual

Page 19: 3 input power, 4 earth ground, Cable requirements

background image

Keri Systems, Inc.

Technical Reference Manual – PXL-250 and SB-293

Revision 5.5

P/N: 01836-004

Page 19

4.0

Cable Requirements

4.1

RS-232 Serial Cable

four conductor, shielded, stranded, AWG 24 wire (such as Belden 9534 or a larger
gauge)

50 feet maximum length (per RS-232 industry specification)

4.2

RS-485 Network Cable

two conductor, shielded, twisted pair, stranded, AWG 24 wire (such as Belden
9501 or a larger gauge)

16,000 feet total network length

refer to the Network Wiring Application Note (P/N 01824-002) for specific
network wiring information

4.3

Input Power

two conductor, stranded, AWG 18 wire (such as Belden 8461 or a larger gauge)

200 feet maximum cable length for systems using an SB-293 with two readers

NOTE: On long power cable runs, the resistance in the cable itself causes a drop in
voltage at the end of the run. Be sure that your power supply does provide 12 VDC at
the end of the cable run.

4.4

Earth Ground

single conductor, AWG 18 wire (or a larger gauge)

1

1. Ground wire is green with or without yellow tracer.

This manual is related to the following products: