TB-5/TB-6 – Reader Connection
The inputs on TB-5 accept wiring from Keri Systems proximity readers or from
Wiegand compatible devices. The standard PXL-250 uses Keri Systems proximity
readers. To use Wiegand compatible devices the Wiegand compatible version of the
PXL-250, the PXL-250W, must have been purchased.
A Wiegand compatible controller will have circuitry installed in the lower left corner
of the PCB, allowing the voltage supplied by the controller to the Wiegand reader to
be changed between 5 VDC and 12 VDC.
Two readers may be installed for one door to allow for access control in both
directions. The "A" reader, allowing entrance, is connected to TB-5 on the PXL-250
motherboard. The "B" reader, allowing exit, is connected to TB-6 on the motherboard.
If your application uses just one reader, connect it to TB-5 on the PXL-250
motherboard.
NOTE: If you are connecting readers for an elevator control application, please refer
to the Elevator Control Application Note (P/N 01878-001) in the appendix of this
document.
9.2.1
Proximity Reader Connection
Refer to Table 3 and Figure 9-3 and make the following connections to attach Keri
Systems proximity readers.
Table 3: Proximity Reader Connections
TB-5/TB-6
Description
Wire Color
Pin 1
Antenna
BLUE
Pin 2
Beeper
GREEN
Pin 3
Reader Power
RED
Pin 4
Reader Ground
BLACK
Pin 5
Green LED
BROWN
Pin 6
Red LED
WHITE
Pin 7
NO CONNECTION
n/a