4 current draw, 5 controller memory retention, 6 output relay contact rating – Keri Systems SB-293 User Manual
Page 18: 7 input device configuration, Table1: proximity reader current draw
Technical Reference Manual – PXL-250 and SB-293
Keri Systems, Inc.
Page 18
P/N: 01836-004
Revision 5.5
3.4
Current Draw
•
maximum current draw 270 mA for a controller plus reader current draw (refer to
Table 1 for Reader current draw)
•
120 mA max for a PXL-250 Controller
•
150 mA max for an SB-293 Satellite Board
NOTE: If an electronic locking device (such as a magnetic lock, a door strike, or
similar device) is to be driven by the same power supply as the PXL-250 controller,
please ensure the power supply provides enough current to drive every device
connected to that supply plus an adequate safety margin. AC power cannot be used.
3.5
Controller Memory Retention
•
5 year lithium battery back up to support controller RAM and real-time clock
3.6
Output Relay Contact Rating
•
1 Amp @ 24 VDC
3.7
Input Device Configuration
•
Door Sense
normally closed
•
Request to Exit
normally open
•
Global Unlock
normally open, or
Auxiliary RTE A-Door
normally open
Table 1: Proximity Reader Current Draw
Reader Type
MS-3000
MS-4000
MS-5000
MS-7000
MS-9000
Current
Draw
50 mA
50 mA
100 mA
200 mA
200 mA