How to Use Axis Update Mode
Before sending the mode command, place the stylus/cursor on the tablet at one of your 
desired grid intersection points. Send the mode command, then the update value. The 
update value is in counts (of resolution) and can be a decimal whole number from 0 to 95. 
(The default is zero.) Add 32 (decimal), a required offset, to the desired update value and 
convert the sum into your preferred number base. For example, if the desired update 
value is 10 (decimal). 
desired increment +32
= increment value in 
decimal 
= increment value 
in hexadecimal 
= increment value 
in ASCII 
 
10
+32
= 42 decimal
= 2A hexadecimal
= ASCII
To disable Axis Update Mode, set the update to zero with the ASCII space character 
As mentioned above, the update value is in counts. The length of a count can vary 
depending on the resolution and measurement system the tablet is using. Therefore, the 
update length can vary. For example: 
Resolution Measurement
System
Update Value (in 
Counts) 
Length of One 
Count 
Update Length
50 lpi 
200 lpi 
US 
US 
5 
5 
0.02 inches 
0.005 inches 
0.1 inches 
0.025 inches 
Combining Axis Update Mode with Other Modes
Point Mode and Axis Update Mode: Invalid combination. Point Mode overrides Axis 
Update Mode. 
 
Remote Request Mode and Axis Update Mode: When the tablet receives a (Remote 
Request) trigger from the host, it issues a report. If the update has not been met 
when the tablet receives this trigger, the tablet reissues the last report. If the 
update has been met when the tablet receives this trigger, the tablet issues an 
updated report. 
 
Stream Mode and Axis Update Mode: The tablet issues a report when the update is 
met. It can issue reports up to the established Report Rate. Also, when pressing a 