GTCO Super L III - Users Guide User Manual
Page 24
Super L III 24
6. Select a predefined (01-89) SuperSet Codes or select one of the User Defined (90-99)
SuperSet Codes to customize.
a. User Defined (01-89) SuperSet Codes are initially read from the tablet when
the Advanced Configuration screen opens. This is to prevent loss of custom
settings. Selecting Read Current Settings from the Options menu will:
i. Read the Power-Up settings and User Defined SuperSet Codes from
the tablet.
ii. Overwrite all Custom Settings not yet saved to the tablet.
b. Restore Factory Settings from the Options menu will prompt for:
i. Power-Up settings reset to factory default and set current.
ii. User Defined SuperSet Codes cleared and reset to factory default.
7. After making your selections, choose one of the following from the File menu at the
top of the screen.
a. Save Temporary Settings will configure the tablet as shown until the tablet
is powered off, reset or another SuperSet Code is selected.
i. After saving temporary settings, select File/Exit to test with other
applications. This will leave the tablet configured to the temporary
settings selected and close the Serial Port, enabling other applications
to communicate with the tablet.
b. Save Power-Up Settings will configure the tablet as shown. Every time the
tablet is powered off and back on or reset, it will restore these settings.
c. Save Custom Settings will reconfigure all nine of the tablet’s User Defined
SuperSet Codes to the settings specified in the corresponding SuperSet Code
dropdown list.
i. You can use the SuperSet Menu on the tablet with the tablet’s
transducer to activate these configurations (S + 90-99).
8. When you have finished, select Exit or Close from the File menu.
a. Exit will close the Tablet Configuration Utilities.
b. Close will exit the Advanced Configuration Screen and return to the Tablet
Configuration Utilities window.