7. Unscrew the Canopy Loop Collar (H ) from the canopy loop. Take
the canopy and pass over the canopy loop. Approximately one half
of the canopy loop exterior threads should be exposed. Adjust until
desired height is reached. *The Canopy loop collar should fit snugly
on the canopy loop after the canopy is installed. Remove Canopy
and Canopy lock collar.
8. Assemble the fixture and have an assistant or a secure support to
hold the weight of the fixture while you complete the wiring
connections. 9.Thread
the fixture wires and ground wire of the assembled fixture through the
canopy loop and nipple and into the outlet box.
CONNECTING THE WIRES (Fig. 2)
10. Attach the power supply wires to the fixture lead wires by
connecting BLACK to BLACK (or SMOOTH) and WHITE to WHITE ( or
RIBBED) .
11. Ground wire connection: Connect the fixture ground wire to house
ground wire, which usually has green or copper insulation, with the
correct size of wire connector. If there is no house ground wire at
ceiling junction box then attach fixture ground wire securely onto
green grounding screw located on the mounting bar.
NOTE: Twist the wires together in the same direction that you twisted
the wire connector onto the wires.
12. Tuck the wire connections neatly into the Junction Box.
Fig. 2
Fixture Name: Wynn 3082-M3/6/8 PW
For Chandelier Light Fixture
WARNING ! SHUT OFF POWER AT FUSE OR CIRCUIT BREAKER.
INSTALLATION INSTRUCTIONS
For Customer Service, contact the place of purchase to arrange for replacement parts.
13. Raise Canopy (G) to the ceiling and secure in place by tightening
the Canopy loop collar (H) into the Canopy Loop (F)
14. Install the light bulbs and glass shade as per the fixture assembly
sheet.
YOUR INSTALLATION IS NOW COMPLETE.
RETURN POWER TO THE JUNCTION BOX AND
TEST THE FIXTURE.
HANGING THE FIXTURE (Fig.1)
1. Carefully remove the new fixture from the carton and the yellow
bag that holds all parts. Check that all parts are included as shown in
the illustration and the Parts and Assembly Sheet.
2. Shut off the power at the circuit breaker and completely remove
the old fixture from the ceiling, including the old mounting strap.
3. Thread Nipple (C) into Canopy Loop (F) until snug.
4. Thread the other end of the Nipple (C) with the canopy loop
attached into Mounting Strap (D).
5. Place Lock Washer (B) over end of Nipple (C) which should
protrude through Mounting Strap (D). Then thread Hex Nuts (A) onto
Nipple (C) until tight.
6. Take this mounting strap assembly and mount to ceiling junction
box with junction box Screws (E). Tighten the screws securely with a
screw driver.
Fig. 1
E
G
C
D
B
JUNCTION
BOX
(CEILING)
A
K
L
H
F