The Verify After Erase checkbox causes the
contents of the program flash and data
EEPROM to be read back after an erase
operation to verify that the device is properly
erased.
The Automatically Read Device Fuses
When Switching To Fuses Tab checkbox
causes the current fuse setting in the device to
be read and used to set the options in the fuse
list each time the fuses tab is displayed.
The Automatically Read Device Lock Bits
When Switching To Lock Bits Tab checkbox
causes the current lock bits setting in the
device to be read and used to set the options
in the lock bits list each time the lock bits tab is
displayed.
Programmer Settings Section
The Programmer drop-down list box specifies
the Digilent programming cable to use for
communication with the device being
programmed.
The Port drop-down list box specifies the
port/device to use from the available devices
installed in the system. This list box is
populated with the corresponding choices for
the cable selected in the Programmer field.
The Settings drop-down list box specifies the
additional settings needed to configure the
selected communications device.
The Configure button, if enabled, displays a
dialog box for configuring the programming
cable.