beautypg.com

Diagnostic charts (cont.) – Carrier 38GXC User Manual

Page 22

background image

22

DIAGNOSTIC CHARTS (CONT.)

Trace connections from
OD board. Connections

ok?

Motor ok.

Fix connection

No

Yes

Yes

No

Replace Motor

No

Visually confirm that fan
blades and outdoor coil
are not blocked.

Clear blockage

Yes

Check motor windings.

Ok?

Trace connections from
OD board. Connections

ok?

Motor ok.

Fix connection

No

Yes

Yes

No

Replace Motor

No

Visually confirm that fan
blades and outdoor coil
are not blocked.

Clear blockage

Yes

Check motor windings.

Ok?

A09370

Fig. 38 – Motors

Check RV connection on

outdoor board. Ok?

Clean or repair the

connection

No

Yes

Yes

Check RV output on outdoor

board. Ok?

No

Replace outdoor board

Replace reversing valve.

Yes

Check RV solenoid. Ok?

Replace solenoid

No

Check RV connection on

outdoor board. Ok?

Clean or repair the

connection

No

Yes

Yes

Check RV output on outdoor

board. Ok?

No

Replace outdoor board

Replace reversing valve.

Yes

Check RV solenoid. Ok?

Replace solenoid

No

A09371

Fig. 39 – Reversing Valve

38/

40GX

C

(Q

)

This manual is related to the following products: