Troubleshooting and Technical Support
This section contains troubleshooting information for your DeviceMaster UP. You should review the following
subsections before calling Technical Support because they will request that you perform many of the
procedures or verifications before they will be able to help you diagnose a problem.
•
•
•
Daisy-Chaining DeviceMaster UP 2E/4-Port Units
If you cannot diagnose the problem, you can contact
Troubleshooting Checklist
The following checklist may help you diagnose your problem:
•
Verify that you are using the correct types of cables on the correct connectors and that all cables are
connected securely.
Note: Most customer problems reported to Comtrol Technical Support are eventually traced to cabling or
network problems.
•
Isolate the DeviceMaster UP from the network by connecting the device directly to a NIC in a host
system.
•
Verify that the Ethernet hub and any other network devices between the system and the DeviceMaster
UP are powered up and operating.
•
Reset the power on the DeviceMaster UP and watch the PWR or Status light activity.
•
If the device has a power switch, turn the device’s power switch off and on, while watching the LED
diagnostics.
•
If the DeviceMaster UP does not have a power switch, disconnect and reconnect the power cord.
•
Verify that the network IP address, subnet mask, and gateway is correct and appropriate for the network.
If IP addressing is being used, the system should be able to ping the DeviceMaster UP.
•
Verify that the IP address programmed into the DeviceMaster UP matches the unique reserved IP
configured address assigned by the system administrator.
•
If using DHCP, the host system needs to provide the subnet mask and gateway.
•
Reboot the system and the DeviceMaster UP.
•
If you have a spare DeviceMaster UP, try replacing the device.
PWR or Status LED
Description
5 sec. off, 3 flashes, 5 sec. off, 3 flashes ... Redboot
™
checksum failure.
5 sec. off, 4 flashes, 5 sec. off, 4 flashes ... SREC load failure.
5 quick flashes
The default application is starting
up.
10 sec. on, .1 sec. off, 10 sec. on .1 sec. off
...
The default application is running.