beautypg.com

Timing diagrams – Cypress CY7C1361C User Manual

Page 25

background image

CY7C1361C
CY7C1363C

Document #: 38-05541 Rev. *F

Page 25 of 31

ZZ Mode Timing

[26, 27]

Notes:

26. Device must be deselected when entering ZZ mode. See Cycle Descriptions table for all possible signal conditions to deselect the device.
27. DQs are in high-Z when exiting ZZ sleep mode.

Timing Diagrams

(continued)

t

ZZ

I

SUPPLY

CLK

ZZ

t

ZZREC

ALL INPUTS

(except ZZ)

DON’T CARE

I

DDZZ

t

ZZI

t

RZZI

Outputs (Q)

High-Z

DESELECT or READ Only

[+] Feedback