Electrical Requirements

Refer to data plate for more information. See “Prod­
uct Data Plate” on page 16 for data plate location.

We recommend that the range be installed with a

power cord set (not supplied). The electrical rating

of the power cord set must be 120/240 volt, 30 am­

peres minimum. The power cord set shall be marked
“For Use with Ranges.” Always use a new power

cord.

Note: In Canada, the range is shipped from the fac­

tory with the range cord already installed.

Ranges are dual rated for use on either 120/240 VAC

or 120/208 VAC. Check the data plate for the kW

rating. Reference the kW rating in the table below to

determine amperage requirements.

Electrical Specifications

VOLTS A.C.

HZ

RATING KW

CIRCUIT BREAKER

120/240

60

6.2

30 AMPS

120/208

60

4.8

30 AMPS

The electrical outlet must be located in the shaded
space shown on the figure in the next column.

Verify that wiring to house is adequate

Contact your local utility company to verify that the
present electric service to your home is adequate. In
some instances, the size of the wiring to the house
and service switch must be increased to handle the
electrical load demanded by the range.

Most wiring codes require a separate circuit with

separate disconnect switch and fuses either in the

main entrance panel or in a separate switch and fuse
box.

The range requires a minimum of a three wire

120/240 or 120/208 volt, 30 AMP, 60 Hz AC circuit.
Check local codes for proper amperage ratings. A

four wire connection is preferred.

Most local building regulations and codes require

that electrical wiring be done by licensed electri­
cians. Be sure to install your range according to the
electric codes in place in your region.

Gas Requirements

A CAUTION

Make certain that gas shutoff valve and all burner con­

trols are in the OFF position before beginning.

Shut off main gas supply valve before disconnecting
the old range and leave it off until the new hook-up

has been completed. Don’t forget to relight the pi­
lot on other gas appliances when you turn the gas

back on.

If not already present, install gas shut off valve in an

easily accessible location.

Make sure all users know where and how to shut off

the gas supply to the range.

Note: The installer should inform the consumer of

the location of the gas shutoff valve.

Important note for LP users

The range is shipped from the factory for use with

natural gas. For use with propane (LP) gas, your
range must first be converted using the LP conver­

sion kit.