4. Remove ground strap from center post, rotate so
that wide end is at top and attach wide end to
range through hole below junction box. Attach
green wire on top of ground strap. Tighten Screw.
5. Attach red wire, round washer, star washer and
nut IN THIS ORDER to left post.
6
.
Attach white wire, round washer, star washer and
nut IN THIS ORDER to center post.
7. Attach black wire, round washer, star washer and
nut IN THIS ORDER to right post.
8
.
Tighten all connections securely and replace ter
minal block cover.
9. Properly secure strain relief (see previous sec
tion).
Note: DO NOT plug in range at this time.
Three Wire Range Cord Connection
The Four Wire Connection (above) is preferred, but
where local codes and ordinances permit grounding
through neutral and where conversion to four wire is
impractical, the unit may be connected to the power
supply via a three wire connection.
1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the
terminal block.
3. Remove top nut, star washer, and round washer
from each post.
Note: DO NOT remove last round washer, last nut or
internal wiring leads.
4. Attach white wire, round washer, star washer and
nut IN THIS ORDER on top of ground strap on
center post.
5. Attach red wire, round washer, star washer and
nut IN THIS ORDER to left post.
6
.
Attach black wire, round washer, star washer and
nut IN THIS ORDER to right post.
7. Tighten all connections securely and replace ter
minal block cover.
tion).
Note: DO NOT plug in range at this time.
11