5

FILTER
RETAINER

FILTER

IN FURNACE

WASHABLE FILTER OR
DISPOSABLE MEDIA
FILTER IN FILTER CABINET

A08589

Fig. 4 -- Filter Installed for Side Inlet

COLLECTOR BOX

TUBE (PINK)

COLLECTOR BOX

TUBE (GREEN)

INDUCER HOUSING

(MOLDED) DRAIN

TUBE (BEHIND

COLLECTOR BOX

DRAIN TUBE)

COLLECTOR BOX

DRAIN TUBE (BLUE)

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

COUPLING (LEFT

DRAIN OPTION)

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

FIELD-INSTALLED

FACTORY-SUPPLIED

1

2

-IN. CPVC STREET

ELBOWS (2) FOR

LEFT DRAIN OPTION

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

COUPLING (RIGHT

DRAIN OPTION)

CAP

COLLECTOR BOX

DRAIN TUBE (BLUE

& WHITE STRIPED)

PLUG

CONDENSATE
TRAP

A01030

Fig. 5 -- Factory--Shipped Upflow Tube Configuration

(Shown with Blower Access Panel Removed)

UNIT DAMAGE HAZARD
Failure to follow this caution may result in noise or furnace

component failure.
The blower wheel should not be dropped or bent as balance

will be affected.

CAUTION

!

g. Clean wheel per instructions on degreaser cleaner. Do

not get degreaser in motor.

9. Reassemble motor and blower wheel by reversing items 8b

through 8f. Ensure wheel is positioned for proper rotation.

Tighten setscrew to between 140--160 in.--lb torque.

NOTE: Be sure to attach ground wire to blower housing.

10. Reinstall blower assembly in furnace.
11. Reinstall control box, transformer, and door switch as-

sembly on blower shelf.

12. Reinstall condensate trap and tubing if previously removed.

a. Reinstall condensate trap in hole in blower shelf.

b. Connect condensate trap drain tubes. See Fig. 5 or

tubing diagram on main furnace door for proper tube
location.

(1.) Connect 1 tube (blue or blue and white striped)

from collector box.

(2.) Connect 1 tube (violet or unmarked) from inducer

housing.

(3.) Connect 1 tube (relief port, green or pink) from

collector box.

NOTE: Ensure tubes are not kinked or pinched, as this will affect
operation.

c. Connect field drain to condensate trap.

13. Reconnect wires. Refer to furnace wiring diagram and con-

nect thermostat leads if previously disconnected. (See Fig.
16.)

NOTE: Refer to Table 3 for motor speed lead reconnection if
leads were not identified before disconnection.

UNIT DAMAGE HAZARD
Failure to adjust the heating speed may shorten heat exchanger

life.
Heating air speed selection MUST be adjusted to provide

proper temperature rise as specified on the rating plate.

CAUTION

!