Installation
Tools and Parts Needed
Additional Parts Needed For
Hard Wire installations
Parts Included
Range Power Supply Cord Kit (240V -30 Amp)
Note: Not necessary for Canadian installations; Canadian units are shipped
with the power cord already installed.
Measuring Tape
Phillips Head Screwdriver
1-1/4” (31.8 mm) Wrench
Pencil
T-20 Torx Screwdriver
Screws (2) and Anchors (2) for Anti-Tip Bracket (Style will vary depending on
mounting surface)
Level
Drill and Drill Bit
Soapy Water
Pipe Wrench
Teflon Tape
Channel Lock Pliers
Gas Leak Test Solution
Gas Supply Line
Gas Shut Off Valve
Safety Gloves and Goggles
Tape (Optional)
Cloth or Cardboard (Optional - to Protect Floor)
Flexible Conduit
Torque Wrench
Note: Power Supply Cord Kit Not Necessary For Hard Wire Installations
Anti-Tip Bracket
Foam Tape
Backwall Trim
Screws for Backwall Trim (2)
Terminal Lugs (For Use With Hard Wire Installations)
Note: not necessary for Canadian installations
General Information
Overall Dimensions
Table 2: Overall Dimensions
Dimension
Inches
centimeters
Height
36”
91.44 cm
Width
31”
78.74 cm
Depth
25 5/8”
65.09 cm
Levei
For best results, cabinets, countertops walls and floors in the installation location
should be as level and plumb as possible. Variance may cause damage to coun
tertops and floors during installation, could jeopardize the seal around the cooktop
and may adversely affect cooking and baking performance.